Covington, GA Electrician Plumber HVAC Service

Book Now

TE Certified provides air conditioning, heating, plumber and electrician services to the residents of Covington, GA and the surrounding areas! For more than 20 years we have been your local choice for repair, replacement, maintenance and inspection of all your home comfort systems.

Area homeowners rely on us to meet all their electrical, plumbing and HVAC needs. Read our reviews and find out why your neighbors consider us to be their nearby home service company in Covington, GA!

Recent Jobs and Reviews in Covington, GA

Rated 5.0 out of 5 stars based on 50 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, knowledge, and expertise demonstrated by the service technicians. A dominant theme throughout the feedback is the emphasis on clear communication, with reviewers frequently praising how thoroughly issues were explained in understandable terms and how various options were presented to help them make informed decisions. The technicians' attention to detail, careful workmanship, and respectful treatment of customers' homes are repeatedly highlighted as standout qualities. Customers also express strong appreciation for the personable and friendly demeanor of the service providers, noting how their approachable attitudes helped ease the stress often associated with home repairs. Punctuality and timeliness emerge as another recurring positive theme, with many reviewers noting that technicians arrived on schedule and completed work efficiently. The level of care and customer service receives particular acclaim, with several customers indicating they would enthusiastically recommend the company to friends and family and expressing intent to use the services again in the future. Overall, the reviews convey a sense of trust, satisfaction, and confidence in both the quality of work performed and the integrity of the service professionals.

Our Local Reviews by City

Job Locations and Reviews

Terrance W.
Terrance W. Checked in
Service Summary / Completed Repairs Came out to address a no-cool condition and performed a full diagnostic of the system. During troubleshooting, I found multiple electrical and control issues that were preventing proper operation. I replaced the failed control board and transformer, then rewired the indoor and outdoor low-voltage circuits according to the manufacturer’s wiring schematic. I also repaired the damaged outdoor thermostat wire to restore proper communication and control between the indoor and outdoor equipment. For added condensate protection, I installed a TE Certified wet switch. This safety device is designed to shut the HVAC system down if water begins collecting in the drain pan, helping reduce the risk of overflow and water damage. I also repaired a damaged supply duct to restore proper airflow and prevent conditioned air from being lost into the surrounding space. During operation, I found the system was low on refrigerant, which is consistent with an existing
Covington, GA 30016
Tyler A.
Tyler A. Checked in
Today’s visit was for the upstairs unit not coming on. Checked thermostat. Inspected the indoor unit. It is a 25 year old furnace. I found the ignition control board is bad. Also no flood protection present. The unit is also undersized on return ductwork. It has 1-12” and 1-8” return. Checked the outdoor unit. Found the condenser coils extremely dirty on both systems. I informed the customer that the board most likely will be unavailable due to age. Also the supply house is closed and would be tomorrow before I could check availability. After discussing things we decided a consultation would be the best course of action. Also we will quote replacement of both units and adding a 3rd system with ductwork for the basement. Got customer scheduled. Thank you for choosing TE Certified
Covington, GA 30014
Terrance W.
Terrance W. Checked in
Came out to a no-cool call. After completing a full diagnostic of the system, I found that the air handler transformer is producing the proper 24 volts, confirming that the low-voltage power supply is present. However, that 24-volt power is not being properly distributed through the air handler control board and Molex connection. Testing across the board showed only approximately 10 volts being passed through where proper 24-volt control voltage should be present. Based on the voltage testing performed today, the air handler control board appears to have failed and is preventing the system from receiving the proper low-voltage signals required for normal operation. The indoor evaporator coil and outdoor condenser coil are both clean and currently free of any major airflow restrictions. Standing refrigerant pressures also appeared normal at the time of testing. Because the system cannot operate properly with the suspected failed control board, I am unable to complete a full operating
Covington, GA 30016
Review
I highly recommend TE Certified! The scheduling staff were pleasant to work with and scheduled us quickly while Marc was wonderful! He completed the repair right after reviewing the issue! And he even put the dig back in place perfectly!
Stephanie P - Covington, GA 30016
Marc T.
Marc T. Checked in
Called out for leak underground at near the meter gave estimate for exploratory dig and to dig and repair service line. Customer agreed I dug down to the service line. Found the leak cut out bad part and installed new fittings section of pipe and shut off with meter box after the meter tested with no leaks at this time and working properly.
Covington, GA 30016
Terrance W.
Terrance W. Checked in
Came out to a no-cool call and performed a full diagnostic on the 2.5-ton Carrier R-410A system. After checking the refrigeration, electrical, airflow, and drainage sides of the system, I found that the unit is extremely low on refrigerant, which indicates an active leak somewhere in the sealed refrigeration circuit. The system itself is relatively new and is still covered under the manufacturer’s parts warranty. Because of that, any failed covered component should be provided under warranty, but labor, refrigerant, recovery, evacuation, and related repair costs are not covered by the manufacturer warranty. I also checked compressor operation. The compressor is starting at approximately 244 amps and settling around 7 amps while running. The condenser data plate lists the compressor at 71.3 LRA, so the startup amperage is significantly elevated. That tells me the compressor is under considerable stress during startup. Before condemning the compressor, I would first correct the refrige
Covington, GA 30016
Mark H.
Mark H. Checked in
Performed diagnostic on 2yr old Goodman heat pump, upon arrival customer stated unit stopped cooling last night, checked both tstats, cycled to ac mode, went to attic to inspect unit, recommend changing 10” bypass to 12”bypass, also recommend adding 10” return for proper airflow, recommend better flood protection such as wet switch, replaced filter, checked evap coil, upon checking outdoor unit found not running, no 240v, found tripped break, reset breaker unit started up, but not compressor, after about 3min compressor kicked in, over amping, also pulling high amps on RLA, turned off to see if compressor would start back up and this time it took about 4min before compressor started up, let unit run to continue diagnostic, checked capacitor, contactor, checked pressures and temp split, after letting unit run for over 30min, shut unit down and started it back up, unit did start right up this time, recommend replacing compressor due to failing, went over all options, customer wanted to h
Covington, GA 30014
Mark H.
Mark H. Checked in
Performed diagnostic on ac unit 20+yrs, unit didn’t have any model or serial number info, couldn’t tell exact age, upon arrival customer stated ac unit was cooling and he not sure how long, checked tstst, recommend updating to digital tstat, cycled to ac mode, unit started up, went to crawlspace to inspect furnace, furnace is older furnace as well no info, blower heavily impacted, burners and heat exchanger heavily rusted, can cause issues going into winter, evap coil heavily rusted, primary drain pan rusted causing water to leak from bottom of evap coil, inspected outdoor unit, condenser fan motor and contactor have been replaced, condenser coil heavily impacted, recommend cleaning coil for accurate pressure readings, checked amp draw, compressor over amping, explained can fail at any moment, upon checking presale temp split, unit is low on r22, explained r22 is obsolete as of 1/1/2020, upon checking temp split at all ducts there are over 5 ducts that have no airflow and 3 return duct
Covington, GA 30016
Greg C.
Greg C. Checked in
Customer called in stating that 2 outlets were not working, one in the garage and one on the back patio. Upon arrival both GFCI outlets were tripped and not resetting. Customer then informed me that they had a surge last week due to a powerful thunderstorm. Apparently there were sparks shooting out of a receptacle upstairs. I did check that outlet and its connections all is good. Recommended them to replace both GFCI outlets and install a surge protection to negate future problems
Covington, GA 30014
Nathan C.
Nathan C. Checked in
No cooling call, upon arrival customer that’s that thermostat went blank, checked 3 amp fuse and found that 3 amp fuse was blown, inspected thermostat wires and found that thermostat was not wired correctly, also found bare thermostat wire going to outdoor unit, replaced small section of thermostat wire, system does not have any flood protection, recommended adding wet switch and inline float switch to prevent water range that can occur due to a clogged drain line, there is also no plenum installed, ducts are coming off of evaporator coil, there should be supply plenum installed in order to get 100% efficiency out of the unit, system is cooling at this time however system is not cooling very well due to improper installation of the ductwork, also found that dual capacitor is bad reading out of tolerance, blower wheel is dirty, recommended replacing system due to not only improper installation but also the age and efficiency rating of the system, system is also short on ductwork all uni
Covington, GA 30016
Nicholas B.
Nicholas B. Checked in
Today we replaced the laboratory faucet on the right hand side of the master bathroom, and rebuilt the upstairs toilet
Covington, GA 30016
Review
Representative was very good and professional
Jeremiah - Covington, GA 30016
Review
Had a shower backed up, Joshuia came out and cleared it right up as well as advised any additional service
Larry - Covington, GA 30014
Review
Thank you for sending Frank by our way. He was knowledgeable, professional, quick, and personable while entering our home.
Daphne - Covington, GA 30016
Review
Excellent
Kevin - Covington, GA 30014
Review
Joshua was polite, efficient, very friendly. Fixed the issue in minimal time
Kathy - Covington, GA 30014
Review
Great service
Elian - Covington, GA 30016
Review
Only bad thing was not being able to know how much sooner but everything was fine
Gary - Covington, GA 30016
Review
Both Cody and Adam were great!
Michael - Covington, GA 30016
Review
My technicians Brandon and Nylan were able to get to my small project the next day. They very friendly, knowledgeable, and fast with their service. Excellent customer service.
Kristina - Covington, GA 30016
Review
Mike was a great technician — very informative, professional, and honest throughout the whole process. He made us feel comfortable, like a friend or uncle stopping by to help rather than someone just trying to sell us services. What I appreciated most was that he never pressured us into unnecessary repairs or extra charges. He explained everything clearly, gave us our options, and left all the final decisions up to us. It’s hard to find that kind of honesty and customer service these days. Highly recommend!
Anthony - Covington, GA 30016